29340 Spherical Roller Thrust Bearing 200 × 340 × 85 mm

Large-bore ISO 104 29340 spherical roller thrust bearing (200 × 340 × 85 mm, 28.5 kg) offering 1,570 kN dynamic and 5,450 kN static axial ratings for vertical hydro-turbine generators and deep-well irrigation pump thrust columns.

Request a Quote

At the top thrust bracket of a small-to-medium vertical Francis/Kaplan hydro-turbine or a high-head deep-well river-irrigation pumping station, dozens of tons of submerged steel shafting, bronze impellers, and continuous downward hydraulic pressure pull vertically without pause across entire irrigation and flood-control seasons. Built to a substantial 200 × 340 × 85 mm ISO 104 boundary (shaft washer B = 53.5 mm, housing washer C = 41 mm, mass 28.5 kg), the ZQM 29340 spherical roller thrust bearing carries 1,570 kN dynamic axial force (Ca) and 5,450 kN static rotor weight (C0a), rated to 950 rpm in cooled oil (700 rpm grease).

29340 Technical Specifications & Dimensions

Data Source: ZQM Factory PDF Catalogue DB (v1)Status: Catalogue Reference ValuesCatalogue Ref: 29340
Parameter CategoryTechnical Parameter (Symbol)Catalogue Reference Value
Boundary Dimensions & WeightBore diameter (d)200 mm
Boundary Dimensions & WeightOutside diameter (D)340 mm
Boundary Dimensions & WeightOverall height (H)85 mm
Boundary Dimensions & WeightInner-ring width (B)53.5 mm
Boundary Dimensions & WeightOuter-ring width (C)41 mm
Boundary Dimensions & WeightInner-ring rib / raceway diameter (d1)306.5 mm
Boundary Dimensions & WeightOuter-ring rib / raceway diameter (D1)257 mm
Boundary Dimensions & WeightReference mass (Weight)28.5 kg
Load Ratings & Limiting SpeedsBasic dynamic load rating (Ca)1570 kN
Load Ratings & Limiting SpeedsBasic static load rating (Coa)5450 kN
Load Ratings & Limiting SpeedsLimiting speed (grease)700 rpm
Load Ratings & Limiting SpeedsLimiting speed (oil)950 rpm
Abutment & Fillet DimensionsShaft abutment diameter (da)265 mm
Abutment & Fillet DimensionsHousing abutment diameter (Da)295 mm
Abutment & Fillet DimensionsMinimum chamfer dimension (r12)4 mm
Abutment & Fillet DimensionsMaximum fillet radius (ra)3 mm
Abutment & Fillet DimensionsAxial offset (S)116 mm

Data source: ZQM Bearings online catalogue database (factory PDF catalogue v1). Load ratings, limiting speeds, and parameters without individual test records serve as catalogue reference values; verify shaft/housing shoulders (da, db, Da), tolerances, internal clearance, and drawings prior to ordering.

Hydraulic Down-Thrust & Anti-Skidding Physics on 200 mm Vertical Columns

Long vertical rotating assemblies experience wide swings between dry-start gravity deadweight and peak-head hydraulic down-thrust, demanding both immense static endurance and strict minimum-load discipline:

  • 5,450 kN Static Deadweight Endurance: During seasonal shutdowns, the entire submerged runner and column shaft rest motionless on the 29340; its 5,450 kN static capacity keeps contact stress comfortably inside elastic limits so restart vibration stays whisper-quiet.
  • Minimum Axial Load (Fa,min) Anti-Skidding Check: Conversely, during pump priming, air-binding, or hydro-turbine runaway transients where hydraulic down-thrust drops sharply, rotor deadweight or preloaded hold-down springs must keep axial load above the catalog minimum threshold (Fa,min) so centrifugal roller inertia never initiates raceway smearing.
  • Column-Plumbness Self-Alignment: Concrete powerhouse piers and deep-well discharge stools settle subtly over decades; the concave spherical housing raceway absorbs modest angular inclination automatically without binding the 200 mm shaft.
  • Submerged Oil-Pot Self-Pumping: Asymmetric barrel rollers pump cooled ISO VG 46/68 turbine oil radially outward across submerged copper water-cooling coils, stabilizing pot temperature cleanly at 500–900 rpm synchronous speeds.

ISO 104 Large-Bore Cross-Reference Table for 29340

Supplier Model Code d (mm) D (mm) H (mm) Hydropower & Pump Column Notes
ZQM 29340 200 340 85 Large-bore ISO 293 series; cage confirmed per order
SKF 29340 E 200 340 85 High-capacity pressed steel or brass cage variant
FAG / Schaeffler 29340-E1 200 340 85 Reinforced roller profile for vertical thrust pots
NSK / NTN 29340 / 29340M 200 340 85 Machined brass cage hydro-pump options
Timken 29340EM 200 340 85 One-piece machined brass cage heavy thrust

Technical cross-reference disclaimer: Equivalence in this table covers ISO 104 nominal dimensions (200 × 340 × 85 mm) exclusively for preliminary sizing. Cage material, oil-submergence slinger geometry, and thrust-collar clearance vary across manufacturers; verify full thrust-pot oil depth and mating sleeve drawings before interchanging brands.

Thrust-Pot Machining, Fit Discipline & Commissioning Rules

  1. Verify Broad Abutment Shoulders & 4.0 mm Chamfer Clearance: Machine the rotating thrust-collar shoulder to at least da = 265 mm and cap the stationary oil-pot seat lip at Da = 295 mm, holding corner fillets strictly underneath the rmin = 4.0 mm bearing chamfer so the heavy 53.5 mm shaft washer seats without localized edge stress.
  2. Separate ISO 286-1 Journal Fit from ISO 1101 Runout: Grind the 200 mm straight cylindrical thrust sleeve to an ISO 286-1 IT6 interference fit so the shaft washer rotates rigidly with the column, while independently dial-checking ISO 1101 thrust-collar face runout and housing-seat flatness across the 340 mm bore.
  3. Dial Oil-Bath Height & Cooling-Water Flow: Fill the thrust pot with rust-and-oxidation-inhibited ISO VG 46 or VG 68 turbine oil so static oil level sits near the roller pitch midpoint; overfilling spikes viscous churning heat and oil misting, while underfilling starves upper roller-rib contacts.
  4. Check Anti-Upthrust Restraint for Transient Valve Closures: Water-hammer surges or check-valve slams can momentarily lift a vertical pump impeller upward. Verify that the upper hold-down bearing is correctly shimmed so reverse lift never unseats the 29340 rollers.

Moisture Ingress, Emulsification & Seasonal Layup Protection

Hydropower galleries and river-intake pump houses operate in high-humidity atmospheres where condensation and pinhole leaks in submerged copper cooling coils contaminate turbine oil rapidly. Free water above 500 ppm triggers hydrogen-embrittlement micro-pitting across hardened bearing steel. Draw quarterly oil samples for Karl Fischer moisture testing, fit desiccant breathers onto the thrust pot standpipe, and rotate idle irrigation pumps by hand several revolutions monthly during off-season layups to recoat rollers.

Pump-Station & Hydro Overhaul Intake

Planning a dry-season hydro-unit overhaul or deep-well irrigation pump refurbishment? Gather four core specs before requesting a quote on 29340 bearings: (1) combined static rotor deadweight plus peak hydraulic down-thrust (kN), (2) synchronous drive speed (rpm) and minimum unloaded thrust condition, (3) thrust-pot cooling method (water coils vs external oil cooler), and (4) preferred cage alloy. Submit your station datasheet via our ZQM heavy-thrust engineering desk.

Sizing Tools & Technical Resources: Run vertical thrust fatigue checks with our ISO 281 Bearing Life Calculator, review verified dimensions at 29340 Catalog Sheet, explore Thrust Roller Bearings, or see right-angle pump-head gear layouts in Industrial Gearboxes & Drives.

Hydro-Turbine & Irrigation Pump Column 29340 FAQ

Why is checking minimum axial load (Fa,min) critical on a 29340 vertical pump column?

When a vertical pump runs momentarily dry during priming or experiences upward hydraulic surge, axial thrust can plunge below Fa,min. Without adequate axial clamping, centrifugal force throws the heavy 28.5 kg roller complement into sliding skid, smearing raceways within minutes.

Can the 29340 operate at 750 rpm in a direct-coupled 8-pole hydro-generator?

Yes—750 rpm sits comfortably below its 950 rpm oil-lubricated limit, though above its 700 rpm grease rating. Submerged oil-bath cooling with water coils or an external heat exchanger is mandatory for continuous 750 rpm generation.

How does cooling-coil water leakage affect a 29340 thrust pot?

Even small cooling-water leaks emulsify turbine oil, collapse elastohydrodynamic film thickness, and accelerate rust pitting during seasonal standby. Pressure-test submerged cooling coils before every overhaul and monitor oil clarity daily via the pot sight glass.

What is the radial load ceiling on a 29340 vertical thrust bearing?

Keep concurrent horizontal radial load strictly at or below Fr ≤ 0.55 Fa. Lateral runner imbalance and hydraulic volute side-loads must be carried primarily by upper and lower radial guide bearings along the vertical shaft column.

Scroll to Top