6320 Deep Groove Ball Bearing 100 × 215 × 47 mm

Heavy ISO 63-series 6320 deep groove ball bearing (100 × 215 × 47 mm, 7.01 kg) delivering 173 kN dynamic radial load and 3,000 rpm grease speed for 250 kW mining ventilation fans and VFD induction motors.

Request a Quote

Running nonstop above an underground coal or metal mine shaft, a 250 kW main ventilation fan motor suspends a heavy copper-wound rotor and massive steel impeller while driven by a pulse-width-modulated variable-frequency drive (VFD). Built in the heavy ISO 63 series at 100 × 215 × 47 mm and 7.01 kg, the ZQM 6320 deep groove ball bearing pairs 173 kN dynamic radial capacity (Cr) and 141 kN static rating (C0r) with a 3,000 rpm grease limit (3,600 rpm oil) to anchor high-torque electric motors reliably across multi-year service intervals.

6320 Technical Specifications & Dimensions

Data Source: ZQM Factory PDF Catalogue DB (v1)Status: Catalogue Reference ValuesCatalogue Ref: 6320
Parameter CategoryTechnical Parameter (Symbol)Catalogue Reference Value
Boundary Dimensions & WeightBore diameter (d)100 mm
Boundary Dimensions & WeightOutside diameter (D)215 mm
Boundary Dimensions & WeightWidth (B)47 mm
Boundary Dimensions & WeightReference mass (Weight)7.01 kg
Load Ratings & Limiting SpeedsBasic dynamic load rating (Cr)173 kN
Load Ratings & Limiting SpeedsBasic static load rating (Cor)141 kN
Load Ratings & Limiting SpeedsLimiting speed (grease)3000 rpm
Load Ratings & Limiting SpeedsLimiting speed (oil)3600 rpm
Abutment & Fillet DimensionsShaft abutment diameter (da)113 mm
Abutment & Fillet DimensionsHousing abutment diameter (Da)202 mm
Abutment & Fillet DimensionsMinimum chamfer dimension (r12)3.0 mm
Abutment & Fillet DimensionsMaximum fillet radius (ra)2.5 mm
Calculation FactorsCalculation factor (f0)13

Data source: ZQM Bearings online catalogue database (factory PDF catalogue v1). Load ratings, limiting speeds, and parameters without individual test records serve as catalogue reference values; verify shaft/housing shoulders (da, db, Da), tolerances, internal clearance, and drawings prior to ordering.

Why 250 kW Mining Fans & VFD Motors Rely on the 6320

Medium-voltage induction motors in 315–355 frame sizes generate substantial rotor dead-weight, aerodynamic suction thrust, and shaft-voltage hazards that lighter 60- or 62-series bearings cannot survive long-term:

  • Heavy 47 mm Raceway Depth: Compared to a 6220 on the same 100 mm shaft, the 6320 expands outer diameter to 215 mm and width to 47 mm, embedding larger steel balls for 173 kN radial endurance against impeller dust-buildup unbalance.
  • Bidirectional Axial Locating via f0 = 13: Deep uninterrupted raceway shoulders lock the rotor axially at the non-drive or drive end, using calculation factor f0 = 13 to evaluate combined radial plus fan-suction axial load accurately.
  • Thermal Clearance Margin (C3 Practice): High-current stator losses warm the 100 mm motor shaft well above the air-cooled cast-iron endshield; specifying C3 radial internal clearance preserves healthy positive operating clearance after shaft press-fit and thermal expansion.
  • VFD Shaft-Current Awareness: Inverter switching induces high-frequency common-mode shaft voltage across the lubricant film. Pairing the 6320 with a shaft grounding brush—or requesting ceramic-coated insulated outer-ring options—prevents EDM frosting and washboard fluting.

ISO 15 Nominal Boundary Cross-Reference for 6320

Brand Base Model d (mm) D (mm) B (mm) Common Motor Execution Options
ZQM 6320 100 215 47 Open catalog base; C3, -2Z, -2RS, M cage per order
SKF 6320 / 6320/C3 100 215 47 Explorer geometry; INSOCOAT available separately
FAG / Schaeffler 6320 / 6320-C3 100 215 47 Generation C low-noise motor grades
NSK / NTN 6320 / 6320C3 100 215 47 Pressed steel or machined brass M-cage options
Koyo / JTEKT 6320 100 215 47 Open, shielded ZZ, and sealed 2RS variants

Interchange statement: Listed codes share the standard ISO 15 boundary envelope (100 × 215 × 47 mm) for baseline identification only. Internal radial clearance (CN vs C3), vibration grade, grease fill, and electrical insulation coatings must match the motor nameplate specification prior to swap-out.

Motor Endshield Installation, Relubrication & Fluting Prevention

  1. Confirm Motor Shaft & Housing Abutments: Hold shaft backing shoulder to da ≥ 113 mm and endshield housing lip to Da ≤ 202 mm, restricting fillet radii to ra ≤ 2.5 mm inside the 3.0 mm minimum bearing chamfer.
  2. Apply Controlled Induction Mounting: For k5/m5 electric-motor shaft interference fits, heat the open 6320 inductively to 95–110 °C (never exceed 120 °C) and slide flush against the 113 mm shoulder without hammering through the balls.
  3. Discipline Polyurea Motor Grease Replenishment: At 1,480 rpm (well below the 3,000 rpm grease ceiling), fill open bearing cavities to 30–35% free volume with polyurea or lithium-complex electric-motor grease (ISO VG 100 base oil) and keep relief ports open during regreasing to prevent over-pressurized churning heat.
  4. Measure Shaft Voltage During Commissioning: On any inverter-driven 250 kW fan, verify peak-to-peak shaft-to-ground voltage with an oscilloscope probe; if voltage climbs above safe thresholds, install a carbon microfiber grounding ring alongside the 6320.

Sourcing C3 electric-motor grade 6320 bearings, machined brass cage variants, or seal-shield options for mine ventilation fleets? Reach our ZQM motor bearing desk with frame size, rpm, and clearance code, or check shaft fits in our engineering tools section.

250 kW Fan & Induction Motor 6320 Engineering Q&A

Related Selection & Comparison: For 120 mm motor shafts carrying heavier rotor weights, compare the 6324 deep groove ball bearing, check all large-bore options in Deep Groove Ball Bearings, or calculate C3 motor fatigue hours in our ISO 281 Life Calculator.

Why do 250 kW induction motors almost universally specify 6320/C3 instead of CN clearance?

A tight shaft press fit expands the 100 mm inner ring while electrical rotor losses heat the shaft hotter than the fan-cooled housing. C3 clearance provides the extra radial room needed so the 6320 never pinches into negative clearance at full load.

How can maintenance engineers spot VFD fluting damage on a 6320 early?

Electrical discharge machining creates microscopic craters that merge into evenly spaced washboard flutes across the raceway, producing a distinct high-frequency whine and elevated broadband vibration long before classic spalling appears.

Should a belt-driven 250 kW fan use a 6320 on the pulley end?

Direct-coupled fans run smoothly on a locating 6320 at both ends (with one floating axially in the housing). However, heavy V-belt overhung pull often exceeds ball-bearing radial life—pair a cylindrical roller bearing (NU 320) at the pulley end with a locating 6320 at the opposite end.

What role does calculation factor f0 = 13 play when sizing the 6320 for fan thrust?

Engineers multiply f0 = 13 by axial fan thrust Fa divided by static rating C0r (141 kN) to look up the axial load threshold e and dynamic load factor Y, ensuring residual impeller thrust does not cut L10h fatigue life unexpectedly.

Scroll to Top